Gear Flow Meters

FL510

Gear Flow Sensor

Positive-displacement dual-gear sensor for continuous or intermittent low-flow measurement of viscous liquids.

CASCED FL510 gear flow sensor
RANGE5 mL/min to 330 L/min across L2–L32 variants
OUTPUTPulse; 4–20 mA; combined pulse/switch/communications options in source
MATERIAL-196°C to +200°C with custom high/low-temperature configuration
PROTECTIONConfiguration-specific

Product overview

Application-focused measurement and switching.

Positive-displacement dual-gear sensor for continuous or intermittent low-flow measurement of viscous liquids.

Configuration note

Ratings, materials, interfaces, and approvals can vary by ordered configuration. CASCED US confirms the controlled specification before order acceptance.

Key features

  • Pulse/analog output options
  • High-pressure and high-/low-temperature options
  • Wide 1:100 turndown as printed
  • Corrosion-resistant options

Technical specifications

Key data for product selection.

Measurement range
5 mL/min to 330 L/min across L2–L32 variants
Outputs
Pulse; 4–20 mA; combined pulse/switch/communications options in source
Accuracy
0.5% FS
Repeatability
0.1% FS
Supply
16–30 VDC
Media temperature
-196°C to +200°C with custom high/low-temperature configuration
Pressure by body
Aluminum 150 bar; stainless steel 400 bar; PP 50 bar
Viscosity statement
Up to 10,000 Pa·s, as printed
Flow equation
Q = f×60/K

Downloads

Technical documentation

View in your browser or download a copy for engineering and sourcing review.

Typical applications

Engineered for real industrial systems.

01Resins and adhesives
02Hydraulic oil and grease
03Fuel oil
04Ink and asphalt
05Solvents and cryogenic fluids
06Batch control

Contact technical sales

Share your operating conditions, interfaces, quantity, and documentation requirements.