Hydrostatic Level Transmitters

LX / LXX

Immersion Level Transmitter

Immersion-style hydrostatic level transmitter using a silicon piezoresistive sensing element and internal temperature compensation.

CASCED LX and LXX immersion level transmitter
RANGECustom liquid depth
OUTPUT4–20 mA; 1–5 V; 0–4.5 V; 0–5 V; 0–10 V
MATERIALGas or liquid non-corrosive to 304 and 316L stainless steel
PROTECTIONIP67

Product overview

Application-focused measurement and switching.

Immersion-style hydrostatic level transmitter using a silicon piezoresistive sensing element and internal temperature compensation.

Configuration note

Ratings, materials, interfaces, and approvals can vary by ordered configuration. CASCED US confirms the controlled specification before order acceptance.

Key features

  • IP67 integrated construction
  • Multiple signal outputs
  • Stainless-steel housing
  • Custom depth range

Technical specifications

Key data for product selection.

Media
Gas or liquid non-corrosive to 304 and 316L stainless steel
Range
Custom liquid depth
Overpressure
200% FS and 300% FS, both printed
Burst pressure
500% FS
Pressure mode
Gauge
Outputs
4–20 mA; 1–5 V; 0–4.5 V; 0–5 V; 0–10 V
Supply
7–36 VDC
Accuracy
±1% FS or ±0.5% FS
Long-term stability
≤±0.2% FS/year typical
Temperature
-40°C to +80°C
Vibration
IEC 60068-2-6, 5–2000 Hz, 20 g
Shock
IEC 60068-2-27, 50 g, 11 ms
Mechanical connection
Flange
Protection
IP67

Downloads

Technical documentation

View in your browser or download a copy for engineering and sourcing review.

Typical applications

Engineered for real industrial systems.

01Pharmaceutical
02Power generation
03Aluminum processing
04Metallurgy
05Municipal water supply

Contact technical sales

Share your operating conditions, interfaces, quantity, and documentation requirements.

Every website inquiry is submitted securely to sales_info@casced.com.