Level and Temperature Switches

NU928

Level and Temperature Switch

Combined float level and temperature switch for mineral oil, gasoline, and water.

CASCED NU928 level and temperature switch
RANGE40°C; 50°C; 60°C; 70°C; 80°C
OUTPUTLevel and temperature switching
MATERIALMineral oil, gasoline, water
PROTECTIONIP65

Product overview

Application-focused measurement and switching.

Combined float level and temperature switch for mineral oil, gasoline, and water.

Configuration note

Ratings, materials, interfaces, and approvals can vary by ordered configuration. CASCED US confirms the controlled specification before order acceptance.

Key features

  • Threaded or three-hole aluminum flange mounting
  • Brass or stainless-steel probe
  • Selectable temperature switch points

Technical specifications

Key data for product selection.

Media
Mineral oil, gasoline, water
Mounting
Thread or three-hole aluminum flange
Probe
Brass or stainless steel
Seal
NBR
Maximum switch current
1 A
Maximum switch voltage
250 VAC
Protection
IP65
Connector
UNI EN 175301-803 (DIN 43650)
Action type
1B
Minimum liquid specific gravity
>0.75
Operating temperature
-20°C to +80°C
Temperature switch options
40°C; 50°C; 60°C; 70°C; 80°C

Downloads

Technical documentation

View in your browser or download a copy for engineering and sourcing review.

Typical applications

Engineered for real industrial systems.

01Industrial tank level and temperature switching

Contact technical sales

Share your operating conditions, interfaces, quantity, and documentation requirements.